{"id":10,"date":"2021-05-12T19:40:55","date_gmt":"2021-05-12T19:40:55","guid":{"rendered":"http:\/\/exio.ie\/?page_id=10"},"modified":"2021-05-18T21:43:07","modified_gmt":"2021-05-18T21:43:07","slug":"plcs","status":"publish","type":"page","link":"https:\/\/exio.ie\/?page_id=10","title":{"rendered":"PLC"},"content":{"rendered":"\n<p>Our choice of PLCs including: Schneider M221, Schneider M241, Schneider M251, Schneider M262.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"1024\" height=\"389\" src=\"http:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/Rang-of-SE-PLCs-1024x389.png\" alt=\"\" class=\"wp-image-154\" srcset=\"https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/Rang-of-SE-PLCs-1024x389.png 1024w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/Rang-of-SE-PLCs-300x114.png 300w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/Rang-of-SE-PLCs-768x292.png 768w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/Rang-of-SE-PLCs-1200x456.png 1200w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/Rang-of-SE-PLCs.png 1525w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><figcaption>Schneider Modicon M221, M241, M251, M262 PLCs<\/figcaption><\/figure>\n\n\n\n<p>Up to 14 I\/O modules per expansion rack, and up to 14 expansion racks per M241\/M262 PLC.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"1024\" height=\"714\" src=\"http:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/TM3-modules-2-1024x714.png\" alt=\"\" class=\"wp-image-214\" srcset=\"https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/TM3-modules-2-1024x714.png 1024w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/TM3-modules-2-300x209.png 300w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/TM3-modules-2-768x535.png 768w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/TM3-modules-2-1200x837.png 1200w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/TM3-modules-2.png 1397w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><figcaption><em>Schneider Modicon TM3 expansion I\/O modules<\/em><\/figcaption><\/figure>\n\n\n\n<p>The M221 compact PLC is suitable for small projects with up to 200 I\/O points, , with performance of <strong>200 ns\/instruction<\/strong>.<\/p>\n\n\n\n<p>The M241\/M251 all around midrange PLC is capable for projects with up to 1,000 I\/O points, with performance of <strong>22 ns\/instruction<\/strong>. <\/p>\n\n\n\n<p>The M262 high performance PLC is suitable for large projects with up to 2,000 I\/O points, with performance of <strong>3 ns\/instruction<\/strong>. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" width=\"1024\" height=\"868\" src=\"http:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/M241-with-multi-racks-1024x868.png\" alt=\"\" class=\"wp-image-203\" srcset=\"https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/M241-with-multi-racks-1024x868.png 1024w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/M241-with-multi-racks-300x254.png 300w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/M241-with-multi-racks-768x651.png 768w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/M241-with-multi-racks-1200x1017.png 1200w, https:\/\/exio.ie\/wp-content\/uploads\/2021\/05\/M241-with-multi-racks.png 1257w\" sizes=\"(max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><figcaption>M241 PLC with multi distributed I\/O racks. Distance between distributed racks up to 80 meters.<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Our choice of PLCs including: Schneider M221, Schneider M241, Schneider M251, Schneider M262. Up to 14 I\/O modules per expansion rack, and up to 14 expansion racks per M241\/M262 PLC. The M221 compact PLC is suitable for small projects with up to 200 I\/O points, , with performance of 200 ns\/instruction. The M241\/M251 all around &hellip; <a href=\"https:\/\/exio.ie\/?page_id=10\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;PLC&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/exio.ie\/index.php?rest_route=\/wp\/v2\/pages\/10"}],"collection":[{"href":"https:\/\/exio.ie\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/exio.ie\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/exio.ie\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/exio.ie\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=10"}],"version-history":[{"count":9,"href":"https:\/\/exio.ie\/index.php?rest_route=\/wp\/v2\/pages\/10\/revisions"}],"predecessor-version":[{"id":217,"href":"https:\/\/exio.ie\/index.php?rest_route=\/wp\/v2\/pages\/10\/revisions\/217"}],"wp:attachment":[{"href":"https:\/\/exio.ie\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=10"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}